Rapid thermal processing (or RTP) refers to a semiconductor manufacturing process which heats silicon wafers to high temperatures (up to 1200 C or greater) on a timescale of several seconds or less. The wafers must be brought down (temperature) slow enough however, so they do not break due to thermal shock..Such rapid heating rates are attained by high intensity lamps process. These processes are used for a wide variety of applications in semiconductor manufacturing including dopant activation, thermal oxidation, metal reflow and chemical vapor deposition.
Rapid thermal anneal (RTA) is a process used in semiconductor device fabrication which consists of heating a single wafer at a time in order to affect its electrical properties. Unique heat treatments are designed for different effects. Wafers can be heated in order to activate dopants, change film-to-film or film-to-wafer substrate interfaces, densify deposited films, change states of grown films, repair damage from ion implantation, move dopants or drive dopants from one film into another or from a film into the wafer substrate. Rapid thermal anneals are performed by equipment that heats a single wafer at a time using lamp based heating that a wafer is brought near. Unlike furnace anneals they are short in duration, processing each wafer in several minutes. Rapid thermal anneal is a subset of processes called Rapid Thermal Process (RTP).
We can provide the following new and refurbished RTP equipment.
The main difference among the above manual desktop Rapid Thermal Processors is as following.
|
Model |
New RTP Systems |
Used RTP System |
|
AccuThermo AW 410 |
AccuThermo AW 610 |
AccuThermo AW 810 |
AG Heatpulse 210 |
AG Heatpulse 410 |
AG Heatpulse 610 |
| Design Year |
2007 |
2006 |
2008 |
1982 |
1984 |
1987 |
| Control Technology |
2000's(AW Advanced) |
2000's(AW Advanced) |
2000's(AW Advanced) |
1980's(PID) |
1980's(PID) |
1990's(PID) |
| Electronic Components |
Modern new components |
Modern new components |
Modern new components |
old and aged components |
old and aged components |
old and aged components |
| Chamber |
Aluminum Plates |
Aluminum Plates |
Aluminum Plates |
Sheet Metal |
Aluminum Plates |
Aluminum Plates |
| Cold Wall |
Cold Wall |
Cold Wall |
Cold Wall |
Cold Wall |
Cold Wall |
Cold Wall |
| High Temperature Sensor |
ERP Pyrometer |
ERP Pyrometer |
ERP Pyrometer |
No |
Single Pyrometer |
Single Pyrometer |
| Pyrometer Calibration |
Easy and precise |
Easy and precise |
Easy and precise |
No |
Difficult and not precise |
Difficult and not precise |
| CE Certification |
Yes |
Yes |
Yes |
No |
No |
No |
| Temperature Range |
100-800 C or 100-1250C |
100-800 C or 100-1250C |
100-800 C or 100-1250C |
100-1000C |
100-800 C or 100-1250C |
100-800 C or 100-1250C |
| Temperature Precision |
+/- 1 C |
+/- 1 C |
+/- 1 C |
+/- 12 C |
+/- 7 C |
+/- 7C |
| Ramp Rate |
10-200 C/S |
10-200 C/S |
10-200 C/S |
10-150 C/S |
10-200 C/S |
10-200 C/S |
| Gases |
1 to 4 with MFC |
1 to 4 with MFC |
1 to 4 with MFC |
1 only with Flow Meter |
1 only with Flow Meter |
1 only with Flow Meter |
| Software |
Advanced AW Software |
Advanced AW Software |
Advanced AW Software |
AG Old Software 1982 |
AG Old Software 1984 |
AG Old Software 1987 |
| Computer |
Embedded control PC |
Embedded control PC |
Embedded control PC |
286 |
386 |
486 |
| Atmosphere |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Wafer Size |
2 to 4 inch |
2 to 4 or 4 to 6 inch |
4 to 6 inch or 5 to 8 inch |
2 to 4 inch |
2 to 4 inch |
2 to 4 or 4 to 6 inch |
| Wafer Shape |
Round or Square |
Round or Square |
Round or Square |
Round or Square |
Round or Square |
Round or Square |
|